Alarms and safeties are changes according to make and model. Here listing out some important alarm and Safeties for marine purifiers.
Safeties In Purifier
> Low pressure switch in the outlet of clean oil
> Emergency Brake
> High pressure switch in the clean oil outlet
> Water transducer to avoid water mixing
Alarms and shut downs
The following gives a general list of alarms only some of which may be fitted.
The following gives a general list of alarms only some of which may be fitted.
> Back Pressure low alarm & shutdown- this measures the discharge oil pressure and alarms and initiates a shut down when below a set value
> Back pressure high alarm & shut down- this measures the discharge oil pressure and alarms and initiates a shut down when the value is higher than set value
Must Read:> Gravity Disc Function, Selection Procedures
seal water pressure means operating water pressure which is used to lift the sliding bowl bottom ??
ReplyDeleteya its operating water. In some purifiers a small header tank is provided with spring air...
Deletebowl not open means, sliding bowl is not discharging sludge in time ...what it is ,i didnt get ,please explain ...
ReplyDeletestriker plate is provided with a lever switch to identify the sludge discharge in correct time. in some other purifiers motor current is monitoring for the same
Deletehope you got it..
ya, i got it thank u..
ReplyDeletecan you differentiate the function of the sealing water and operating water in an oil purifier..??
ReplyDeletesealing water provides to make the interface at the starting of purifier.
Deleteoperating water helps to opening and closing of bowl while desludge
In an oil purifier, what are the probable causes if light phase liquid is observed to be exiting from the heavy phase liquid outlet..??
ReplyDeleteit may becoz of lot many reasons... gravity disk size,temperature, back pressure etc..
DeleteAlarm - " clean oil discharge pressure low " any troubleshooting solution please
ReplyDeleteI think purifier is alcap model... U need to adjust through put and back pressure
Deleteit's westfalia purifer , osd60 model
ReplyDeleteyeah, its westfalia, "clean oil discharge pressure low" normally comes when there is a prblm with back pressure.. is there any overflow through sludge port? how much time it will run with out any alarms? have you checked the back pressure sensor? can you please elaborate little more about your problem?
Deletepurifier bowl not opening reason ?
ReplyDeletethis is because of lot many reasons like, leaky orings, solinoidal valves malfunctioning, operating water pressure low, drain of operating water get chock etc.
DeleteWhat are the reasons of alarm A7-10 in
ReplyDeleteHfo purifier model FOPX-609
During a normal sludge discharge, displacement water is added to the bowl for a pre-defined amount of time. Typically during this time, the water transducer MT4 will begin to detect a slight increase in the water content of the oil as the oil/water interface moves inward due to the added displacement water. When this change occurs, the system initiates a "shoot" momentarily opening the bowl to purge the accumulated sludge/water/dirt.
ReplyDeleteIf, for some reason, that increase in the water content of the oil explained above is not detected within the preset duration of displacement water (parameter P70) after two consecutive discharges, an A7-10 alarm will be triggered.
As explained in the Alfa-Laval manual, this could be caused by a faulty bowl seal that is allowing water leakage before it can be detectd by the water transducer. Another cause may be a malfunctioning displacement water supply or a breakdown of seperator internals such as the pairing disc or pairing chamber cover that are a part of water removal system. The manual warns that non-remedied A7-10 alarms run the risk of causing equipment breakdown
Westfalia lub oil separator given alarm water overflow what is the reason?
ReplyDeletemay because of the wrong adjustment of back pressure or gravity disc
DeleteAlarm 48 water discharge overflow apa penyebab nya
ReplyDeletemay because of the wrong adjustment of back pressure or gravity disc
DeleteThank you
ReplyDeleteHello I got an alarm stating "ejection monitoring alarm" on westfalia OD60. I already tried changing gasket of bowls, replaced clutch shoes, and gaskets, and still has alarm. What could be the other causes of this..?
ReplyDeleteIs this problem is sorted out?. If so please share your experience.
Deletepurifier gives no discharge alarm... What can be the causes???
ReplyDeleteThere is abnormal water content in the dishcarge of my lube oil purifier, I already changed the Orings and the Gravity disc. Hidens alarm still triggers. The solenoid valves of operating waters seem ok. What should I do? I tried everything