While Engine Is Running
> While engine is operating hand touch the adjacent pipe, if its hotter than others it leaks
In Port
> Open indicator cocks of all unit
> Close isolating valve to air pilot distributor
> Open main air bottle valve
> Set the control lever to start position
> If any air escapes through indicator cock shows that unit's start air valve is leaky